Mahmoud Mossa:Control of a Wind Driven Doubly Fed Induction Generator During Grid Faults
- Pasta blanda 2013, ISBN: 3656368384
[EAN: 9783656368380], Neubuch, [SC: 0.0], [PU: GRIN Verlag], Druck auf Anfrage Neuware - Printed after ordering - Master's Thesis from the year 2013 in the subject Engineering - Power Eng… Más…
[EAN: 9783656368380], Neubuch, [SC: 0.0], [PU: GRIN Verlag], Druck auf Anfrage Neuware - Printed after ordering - Master's Thesis from the year 2013 in the subject Engineering - Power Engineering, grade: none, , course: Electrical engineering (Renewable energy), language: English, abstract: Wind electrical power systems are recently getting lot of attention, becausethey are cost competitive, environmental clean and safe renewable powersource, as compared with fossil fuel and nuclear power generation. A specialtype of induction generator, called a doubly fed induction generator (DFIG),is used extensively for high-power wind applications. They are used moreand more in wind turbine applications due to ease controllability, highenergy efficiency and improved power quality.This thesis aims to develop a method of a field orientation scheme forcontrol both the active and reactive powers of a DFIG driven by a windturbine.The proposed control system consists of a wind turbine that drives aDFIG connected to the utility grid through AC-DC-AC link. The maincontrol objective is to regulate the dc link voltage for operation at maximumavailable wind power.This is achieved by controlling the and axescomponents of voltages and currents for both rotor side and line sideconverters using PI controllers. The complete dynamic model of theproposed system is described in detail. Computer simulations have beencarried out in order to validate the effectiveness of the proposed systemduring the variation of wind speed. The results prove that , better overallperformances are achieved, quick recover from wind speed disturbances inaddition to good tracking ability.Generally, any abnormalities associated with grid asymmetrical faults aregoing to affect the system performance considerably. During grid faults,unbalanced currents cause negative effects like overheating problems andmechanical stress due to high torque pulsations that can damage the rotor shaft, gearbox or blade assembly. Therefore, the dynamic model of theDFIG, driven by a wind turbine during grid faults has been analyzed anddeveloped using the method of symmetrical components. The dynamicperformance of the DFIG during unbalanced grid conditions is analyzed anddescribed in detail using digital simulations.A novel fault ride-through (FRT) capability is proposed (i.e. the ability ofthe power system to remain connected to the grid during faults) with suitablecontrol strategy in this thesis. In this scheme, the input mechanical energy ofthe wind turbine during grid faults is stored and utilized at the moment offault clearance, instead of being dissipated in the resistors of the crowbarcircuit as in the existing FRT schemes. [.] 140 pp. Englisch, Books<
| | ZVAB.comAHA-BUCH GmbH, Einbeck, Germany [51283250] [Rating: 5 (von 5)] NEW BOOK. Gastos de envío:Versandkostenfrei. (EUR 0.00) Details... |
(*) Libro agotado significa que este título no está disponible por el momento en alguna de las plataformas asociadas que buscamos.
Control of a Wind Driven Doubly Fed Induction Generator During Grid Faults
- libro nuevo2013, ISBN: 9783656368380
Master's Thesis from the year 2013 in the subject Engineering - Power Engineering, grade: none, , course: Electrical engineering (Renewable energy), language: English, abstract: Wind elec… Más…
Master's Thesis from the year 2013 in the subject Engineering - Power Engineering, grade: none, , course: Electrical engineering (Renewable energy), language: English, abstract: Wind electrical power systems are recently getting lot of attention, because they are cost competitive, environmental clean and safe renewable power source, as compared with fossil fuel and nuclear power generation. A special type of induction generator, called a doubly fed induction generator (DFIG), is used extensively for high-power wind applications. They are used more and more in wind turbine applications due to ease controllability, high energy efficiency and improved power quality. This thesis aims to develop a method of a field orientation scheme for control both the active and reactive powers of a DFIG driven by a wind turbine.The proposed control system consists of a wind turbine that drives a DFIG connected to the utility grid through AC-DC-AC link. The main control objective is to regulate the dc link voltage for operation at maximum available wind power.This is achieved by controlling the and axes components of voltages and currents for both rotor side and line side converters using PI controllers. The complete dynamic model of the proposed system is described in detail. Computer simulations have been carried out in order to validate the effectiveness of the proposed system during the variation of wind speed. The results prove that , better overall performances are achieved, quick recover from wind speed disturbances in addition to good tracking ability. Generally, any abnormalities associated with grid asymmetrical faults are going to affect the system performance considerably. During grid faults, unbalanced currents cause negative effects like overheating problems and mechanical stress due to high torque pulsations that can damage the rotor shaft, gearbox or blade assembly. Therefore, the dynamic model of the DFIG, driven by a wind turbine during grid faults has been analyzed and developed using the method of symmetrical components. The dynamic performance of the DFIG during unbalanced grid conditions is analyzed and described in detail using digital simulations. A novel fault ride-through (FRT) capability is proposed (i.e. the ability of the power system to remain connected to the grid during faults) with suitable control strategy in this thesis. In this scheme, the input mechanical energy of the wind turbine during grid faults is stored and utilized at the moment of fault clearance, instead of being dissipated in the resistors of the crowbar circuit as in the existing FRT schemes. [...] Bücher > Fremdsprachige Bücher > Englische Bücher 210 x 148 x 9 mm , GRIN, GRIN<
| | Orellfuessli.chNr. A1028838226. Gastos de envío:Lieferzeiten außerhalb der Schweiz 3 bis 21 Werktage, , Versandfertig innert 4 - 7 Werktagen, zzgl. Versandkosten. (EUR 17.82) Details... |
(*) Libro agotado significa que este título no está disponible por el momento en alguna de las plataformas asociadas que buscamos.
Mahmoud Mossa:Control of a Wind Driven Doubly Fed Induction Generator During Grid Faults
- Pasta blanda 2013, ISBN: 9783656368380
Paperback, [PU: Grin Publishing], Master's Thesis from the year 2013 in the subject Engineering - Power Engineering, grade: none, course: Electrical engineering (Renewable energy), langua… Más…
Paperback, [PU: Grin Publishing], Master's Thesis from the year 2013 in the subject Engineering - Power Engineering, grade: none, course: Electrical engineering (Renewable energy), language: English, abstract: Wind electrical power systems are recently getting lot of attention, because they are cost competitive, environmental clean and safe renewable power source, as compared with fossil fuel and nuclear power generation. A special type of induction generator, called a doubly fed induction generator (DFIG), is used extensively for high-power wind applications. They are used more and more in wind turbine applications due to ease controllability, high energy efficiency and improved power quality. This thesis aims to develop a method of a field orientation scheme for control both the active and reactive powers of a DFIG driven by a wind turbine.The proposed control system consists of a wind turbine that drives a DFIG connected to the utility grid through AC-DC-AC link. The main control objective is to regulate the dc link voltage for operation at maximum available wind power.This is achieved by controlling the and axes components of voltages and currents for both rotor side and line side converters using PI controllers. The complete dynamic model of the proposed system is described in detail. Computer simulations have been carried out in order to validate the effectiveness of the proposed system during the variation of wind speed. The results prove that, better overall performances are achieved, quick recover from wind speed disturbances in addition to good tracking ability. Generally, any abnormalities associated with grid asymmetrical faults are going to affect the system performance considerably. During grid faults, unbalanced currents cause negative effects like overheating problems and mechanical stress due to high torque pulsations that can damage the rotor shaft, gearbox or blade assembly. Therefore, the dynamic model of the DFIG, driven by a wind turbine during grid faults has been analyzed, Technology: General Issues<
| | BookDepository.comGastos de envío:Versandkostenfrei. (EUR 0.00) Details... |
(*) Libro agotado significa que este título no está disponible por el momento en alguna de las plataformas asociadas que buscamos.
Mahmoud Mossa:Control of a Wind Driven Doubly Fed Induction Generator During Grid Faults
- Pasta blanda ISBN: 3656368384
Control of a Wind Driven Doubly Fed Induction Generator During Grid Faults ab 54.99 € als Taschenbuch: 1. Auflage. Aus dem Bereich: Bücher, Taschenbücher, Naturwissenschaft, GRIN Verlag
| | Hugendubel.deNr. 20274533. Gastos de envío:, , DE. (EUR 0.00) Details... |
(*) Libro agotado significa que este título no está disponible por el momento en alguna de las plataformas asociadas que buscamos.
Mossa, Mahmoud:Control of a Wind Driven Doubly Fed Induction Generator During Grid Faults
- libro nuevo 2013, ISBN: 3656368384
1. Auflage Kartoniert / Broschiert, mit Schutzumschlag 11, [PU:GRIN Verlag]
| | Achtung-Buecher.deMARZIES.de Buch- und Medienhandel, 14621 Schönwalde-Glien Gastos de envío:Versandkostenfrei innerhalb der BRD. (EUR 0.00) Details... |
(*) Libro agotado significa que este título no está disponible por el momento en alguna de las plataformas asociadas que buscamos.